. Preliminary. Contents Information.Technical And Operational Description. Connections.Card Data Format.Demo Software. Specifications.Communication Protocol.USB Driver Setup.23 FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. Information Mini123 Series Magnetic Swipe Reader MACHINE TYPE FUNCTION LOW BAT F - MEM BATTERY 2032 2032 512 KB 1 2 3 LED STATUS RS-232 2048 REC QUEUE POWER AUTO Ver 1.1 BEEP VER 1.2 Mini123 Track 1 & 2 & 3 Lithium Coin For Mini123 Reader Replacement battery information Nominal. Information Standard Package Battery 3V ( BAT-T0004 ) Main unit ( Mini123 ) CD-ROM ( DISK5196 ) RS232 Cable ( WAS-1543 ) Chain Sling Option USB Cable ( WAS-1571 ) - 2.
Portable Card Reader MSR500m (Mini123SC-K) old Version K Firmware R18. New and under full warranty.
Technical And Operational Description Front Panel Display and Operations CARD READER STATUS INDICATOR CONNECTOR POWER BUTTON BATTERY CARD READER Swipe the card through the entire length of the slot to read. STATUS INDICATOR ( Red color ) When encountering erroneous input, defective card, misread, low battery,bad memory or incorrectly encoded data and so on, the device will turn on the ERROR indicator. Technical And Operational Description Display Information Status Green LED Red LED Read Card Power On Take turns blink 2 times Auto Power Off Take turns blink 2 times Ready Read OK Blink 1 times Read Error Blink 1 times Low Battery Blink Inactive Battery Blink 3 times. Technical And Operational Description Replace Battery 5. Take new battery 1. Turn off power Note Positive electrode direction 6.
Put new battery in 2. Press the cover down to take off the battery cover 7. Press the battery down firmly 3. Connections WAS-1543 1500+-30 DSB 9P FEMALE PIN FUNCTION MINI USB 4P. DSB 9P FEMALE Pin 4 for power supply Connect to PC RS-232 PORT External Power Powered form PC COM port Note: When you use the application software to save the data, all records stored in Mini123 will be deleted automatically after saving. For this procedure consumes much power, Mini123 will reset itself if the PC COM Port does not provide enough power supply.
Connections WAS-1571 USB 4P FEMALE PIN FUNCTION MINI USB 4P FUNCTION Connect to PC PORT External Power Powered form PC COM port Note: When you use the application software to save the data, all records stored in Mini123 will be deleted automatically after saving. For this procedure consumes much power, Mini123 will reset itself if the PC COM Port does not provide enough power supply. Card Data Format CARD DATA STRING TRACK 1 TRACK 2 TRACK 3 DATE & TIME TRACK1 DATA TRACK2 DATA TRACK3 DATA DATE TIME WEEK TRACK1 DATA TRACK2 DATA TRACK3 DATA DATE TIME WEEK TRACK 1 CARD ID Track 1 IATA Bits Per Inch Bits Per Character 1. Demo Software STEP 1: RUN Mini123 START Mini123 SOFTWARE STEP 2: CHOOSE COM PORT (Do not choose TCP/IP). BAUDRATE: 9600 BPS CHOOSE COM PORT - 9.
Demo Software STEP 3: ENTER SET TIME TO SET PC CURRENT TIME TO Mini123 ( WHEN NEEDED) NOTE: MAKE SURE YOUR PC CURRENT TIME IS CORRECT BEFORE YOU SET PC TIME TO Mini123. ENTER SET TIME STEP 4:ENTER GET TIME ( TO SHOW THE DATE&TIME IN Mini123 WHEN NEEDED) SHOW THE DATE&TIME IN Mini123. Demo Software STEP 6: ENTER POWER MODE (Timer set min 10 second /max 30 minute) ENTER POWER MODE STEP 7: ENTER USER NAME, CURRENT USER NAME DISPLAY USER NAME ENTER USER NAME - 11. Demo Software STEP 8: ENABLE PASSWORD FUNCTION NOTE: IF YOU RESTART Mini123 SOFTWARE, YOU HAVE TO ENTER PASSWORD THEN AFTER YOU HAVE ENABLED PASSWORD FUNCTION. Setting password Function Enable STEP 9: CHANGE PASSWORD AND SET UP PASSWORD HINT. Change Password Default is.
Demo Software STEP 10: THE FUNCTION OF PASSWORD HINT. Enter password hint for reminding of password Enter correct password according to the showed hint, and it will enter Mini123 program. STEP 11: ENTER UPLOAD TO UPLOAD DATA DATE UPLOAD DATA PRESS. Demo Software STEP 12: ENTER SAVE TO SAVE DATA ( Pls refer to the remarks Connect to PC in page 8. ) CURRENT FILENAME ENTER SAVE STEP 13: SAVE DATA TO A FILE DATA STEP 14: EXIT Mini123 SOFTWARE ENTER EXIT ENTER. Specifications Magnetic Stripe Card: TRACK 1 / IATA / 210 bpi / 79 Alphanumeric Characters 1 2 3 TRACK 2 / ABA / 75 bpi / 40 Numeric Characters TRACK 3 / Thrift / 210 bpi / 107 Numeric Characters RS232 Interface: RS-232 RS232, Half-Duplex, 8N1, 9600 bps. Communication Protocol GNET FEATURES Support TTY (TELE TYPE) OPERATION - Use TTY to send commands and messages.
Simple handshaking - One enquiry one answer back. Multi-link capability Expandability - GNET provides 4 major functions: GNET 1.
LOGIN / LOGOUT V1.2 3. Communication Protocol Command Index Table Topic Command Contents Description Get Product Version Date,Time,Week Set Date,Time and Week SETTING Get Date and Time Number+Param+ChkSum Set Register by Number Number Get Register by Number Get Number of Record DATABASE Number Read Record by Number Erase All Record Reply Index Table Topic. Communication Protocol 1. GET NUMBER OF RECORD: NUMBER CHKSUM NUMBER Record Count.
4 Bytes Width ( 0000h 0080h ) EXAMPLE 000C The Total of Record Count: 12 2. READ RECORD BY NUMBER: NUMBER NUMBER DATA CHKSUM NUMBER Record Count. Communication Protocol 4. SET DATE AND TIME: YYYYMMDDhhmmssw Week YYYY Year (1980 - 20xx ) Month (01 - 12 ) Date ( 01 - 31 ) Hour ( 00 - 23 ) Mintue ( 00 - 59 ) Second ( 00 - 59 ) Week ( 1 - 7 ) EXAMPLE 30006. Communication Protocol EXAMPLE V1.0R00 Firmware Version = 1.0 Modify times = 0 7. SET REGISTER: REGISTER PARAM CHKSUM REGISTER Register Address. 2 Bytes Width ( 00h FFh ) PARAM Set Parameters of Register CHKSUM C + REGISTER +, + PARAM 7-1.
Communication Protocol EXAMPLE Modem: 2400 Non- modem: 9600 Write to Parameter Table Address: 10 h Auto Power Off Time (Low Byte): 5 Seconds 7-3. SET AUTO POWER OFF TIME (HIGH BYTE): SECH CHKSUM SECH '00-FF' (00-FF)/2.256 Seconds EXAMPLE Modem: 2400. Communication Protocol EXAMPLE Modem: 2400 Non- modem: 9600 Write to Parameter Table Address: 12 h Get Power Mode: Real Control 8-2. GET AUTO POWER OFF TIME (LOW BYTE): SECL CHKSUM Same 7-2. SET AUTO POWER OFF TIME (LOW BYTE ) EXAMPLE Modem: 2400 Non- modem: 9600. USB Driver Setup Driver Software Installation - For WAS-1571 only 1.Connect WAS-1571 into the USB PORT of your Computer first. 2.Under Windows 98/2000/Me/XP,put DISK5196 into the cd-rom disk driver,it will automatically install the USB232/422/485 Driver Software into your Computer by following the steps as below: 1.
USB Driver Setup 3. Select Searching locations for new driver Give the path location Select this Click Next 4. Windows is now ready to install the best driver Device name Path location Click Next - 24. USB Driver Setup 5. Windows has finished installing the software Finish driver software installation Click Finish - 25. USB Driver Setup 6.
Make sure if the driver software installation is finished Connect WAS-1571 unit into the USB port of the computer and then Click ' Start ' -' Settings ' - ' Control Panel ' - ' System ' -' Device Manager '.